Hello 73lafuite,
Many thanks for your quick response! Please find my replies in Red below:
Do not worry the D7300 or D7765 distributors have no internal leaks, even if the symbol on D7300 is poorly represented.
Great! I thought there was something I was missing with the weird check valve...
Hi Hamza,
I am going to make two assumptions here.
[1]The hydraulic actuator in question is a linear double acting hydraulic cylinder and not a hydraulic motor.
[2]Closing of butterfly valve is during retraction stroke of cylinder. (My argument still applies even if closing is during...
Hi 73lafauite,
Thank you for your response. I was of the opinion of using the same manufacturer (HAWE) but have been referring a different datasheet D7300. I have attached this here for your reference. If you look at "Table 1: Flow Pattern" on page 2; under "3/2-way valves", you will find...
Hello,