  1. CLFletch

    drawing callout for UT inspection

    From the drawing I would assume the marked surface as being the area of interest. However as a UT tech I would need a lot more information (equipment requirements, probe angle, ect...) which may be contained in the DIN spec stated at the bottom (this also very likely contains your acceptance...
  2. CLFletch

    UCS-85 question

    You should refer to SA-516-70 of ASME Section II-A. This will define what is required on the MTR to conform to the material specification.
  3. CLFletch

    ASME II-D, subpart 3 - definition of P.L.

    Just a guess but I believe it is referring to proportional limit. I base this assumption off of Sect II D Appendix 3
  4. CLFletch

    How does Division 1 handle external blind holes in flange covers?

    Closest I can think of is UG-43 (d), though I am not positive it would be considered a studded connection. You may also reference the standard the flange is made to (B16.5), and make sure the flange is still acceptable to use under its rating...