  1. BurnieC

    Does anyone have the complete Sadovsky formula for over-pressure?

    I only have a version with equivalent mass in air at atmospheric pressure. I need to make a calculation in water at pressure....
  2. BurnieC

    ASME Section VIII Div 1 & 2 with API 6AX Stress Allowables

    Hi jmec87, Thank you very much for that informative post. I did mean 6X but did not realise it was not applicable to 6A - I should be using API 6A section 4.3. My main problem then comes from it being an allowable stress intensity. Some calculations such as the pressurised cylinder thickness...
  3. BurnieC

    ASME Section VIII Div 1 & 2 with API 6AX Stress Allowables

    Personally I wouldn't but I'm reviewing a whole set of calculations which I do not think are correct. I believe it is done because a valve is supplied to API 6A standards but the calculations are mostly ASME Div 1 or Div 2, hence the 'justification' for using 6A allowables on ASME calcs. Still...
  4. BurnieC

    ASME Section VIII Div 1 & 2 with API 6AX Stress Allowables

    Hi everybody, API 6AX states that stress intensity allowables are 2/3 yield at operating and 5/6 yield at hydrostatic test. When designing using ASME Div 1 & Div 2 it states to check stresses against allowables in ASME Section II Part D. Taking Div 2 as an example these are the minimum of...