Hi everyone.
We have overhang pump with double mech seal. Plan 53B.
Ps=150kpa
Pd=690kpa
Fluid=amine(40%amine+60%water)
T=80C (but as per DS should be 46,5C)
Double mechanical tandem seal EagleBurgman.
As per EB datasheet seal chamber pressure 170kpa, Max.451kpa. So seal pressure...