    Plan53B external leak

    Hi everyone. We have overhang pump with double mech seal. Plan 53B. Ps=150kpa Pd=690kpa Fluid=amine(40%amine+60%water) T=80C (but as per DS should be 46,5C) Double mechanical tandem seal EagleBurgman. As per EB datasheet seal chamber pressure 170kpa, Max.451kpa. So seal pressure...