Hello guys,
for a Hardware-in-the-Loop simulation, I need to operate a Kollmorgen DBL servo motor in torque-control mode. The problem is, that these motors use the motor current to estimate the torque at every instant. However, I would prefer to use one of the servo drives inputs for an...
Hi guys,
I am planning to operate 4x Kollmorgen servo motors each with a rated power of 1000-5000W. Since the motors will the most time be stationary while providing a constant torque, I want to add a separate, external ventilation system to each one of these.
I can't find any adeqaute...
Alright got it :)
Last question: what about the neutral N cable of the power supply? Can I just neglect it?
I ask because this drive supports both TT and TN networks
Thanks
Thanks for both responses.
Alright, so I have to connect the ground stud of the drive to the encloseure's ground stud.
Now, the power comes from a 3P+N+E socket. According to the wiring diagram (which I uploaded here):
--the three phases have to first pass through a fuse and then be connected...
Hello guys
a few years ago I bought a Kollmorgen DBL4N00260 servo and a Servostar 603 servo drive. I have not tried to setup the system yet. Although there are many safety instructions in the manual, I am not sure about a few things: