  1. C-Su

    Quick exhaust is not recommended for Anti-Surge Valves

    Hi, Gerhardl Totally agree with you. I have gotten the answer of my question. The answer is the quick exhaust valves can be used to Anti-surge valve. As for why the quick exhaust valves are forbidden, the reason is very funny. The root cause is that our assemblers very often connected the...
  2. C-Su

    Quick exhaust is not recommended for Anti-Surge Valves

    Hi, Gerhardl Thank you for your fast reply! Yes, You are right, it is a double acting pneumatic actuator. The image is the schematic of original design. img https://res.cloudinary.com/engineering-com/image/upload/v1556501333/tips/schematic_ns8q4v.png] and the valve shall act as below: 1...
  3. C-Su

    Quick exhaust is not recommended for Anti-Surge Valves

    I am working on a pneumatic loop for An anti-surge valve. i used a quick exhaust valve to seep up the exhausting. but An senior engineer told me that Quick exhaust valves would be not recommended for Anti-Surge valve and they would be forbidden to be used. And the reason is that the quick...