Dear PetroDDp,
i have been working on Kero Merox Unit for the last 5 years. We face the same problem time to time. But never heard of any online analyzer, have to rely on laboratory.
Abdul Rauf
Dear EdStainless,
Yes, all the damage is at eye. The edges of the inducer have some material loss as well.
I have checked the flow history of the pump. The flow varied from 17 to 38 m3/h with normally @ 27 ~ 30 m3/h. Average pH of the fluid ~10.8. This pump has a history of seal leakage.
Abdul...
Hi Everyone!
We have a sundyne pump at Crude Distillation Unit to inject stripped water to desalters.. The pump was opened due to seal leakage issues. Internal Inspection revealed damage to impeller and Inducer.
Following are the process conditions
Serive : Stripped Water
pH : 10.5 to 11.0 on...