  1. HTURKAK

    Seal (mud) Slab or CSS Pad?

    So you don't have borehole specific for the culvert location. My vote would be 300 mm compacted crushed stone ( ballast ) bedding + 75 mm blinding layer. I will suggest you at least ; see the excavation and decide as per site conditions. If the soil stiff clay , alluvium soil , extend...
  2. HTURKAK

    Concurrent Active and Counteractive Dead Load

    I do not know Canadian Building Codes and i have experience with Eurocodes . Regarding the terms active and counteracting dead loads, EC uses favorable and unfavorable dead loads. The favorable and unfavorable dead loads are not additive , and shall be used for different load...
  3. HTURKAK

    Nonstructural Components or Nonbuilding Structures, Building Safety Journal

    I do not have any idea how did you search. Pls find below the pdf copy attached.
  4. HTURKAK

    Bolt capacity in hand-tightened condition

    I agree with BridgeSmith . When you consider the failure modes ( Shear of the bolt, Bearing failure , • Block tearing ) still applicable except slipping . I will suggest splicing the flanges after casting and curing the concrete to avoid moment connection.
  5. HTURKAK

    Longitudinal shear between web and flange of T-beam

    In addition to hogging reinf. of slab , in general , half of the slab span reinf. extends to support which compression force develops for these bottom reinf. Can you show a real case where Max(rebar for longitudinal shear,0.5×rebar for longitudinal shear+rebar for transverse bending) or rebar...
  6. HTURKAK

    Interesting Footing retrofitting situation - Extending Existing retaining wall pier foundation under earth

    Apparently you are planning only to increase the footprint of the pier footing and IMO , it is not good idea . I would consider the following two options before increasing the footing sizes , - The use of tieback anchor block for each pier . If slit trenching and installation of anchor...
  7. HTURKAK

    Longitudinal shear between web and flange of T-beam

    I have old copy of EC-2 ( EN 1992-1-1:2004 Incorporating corrigendum February 2014) . Although it is not explicitly stated, as far as i understand , clause 6.2.4 Shear between web and flanges is for T-beams cast monolithic with slab . I would like point out the clause (6) If vEd is less...
  8. HTURKAK

    Frost heave in saturated gravel below foundation

    The gravel is not frost susceptible as long as not submerged . In your case , gravel will be submerged and will be frost susceptible . I will recommend that the bottom of PC pier shall be below frost depth. Extending the excavation level below the frost depth should not be big issue.
  9. HTURKAK

    AWWA C200 Pipe Welding

    A profile of the pl would be more helpful to see the problem. As per the info. provided by OP , the extended portion will also be gravity flow . I would consider other jointing and pl materials and avoid welding . Two options ; - Use VJ coupling and in this case the extension pipe could be...
  10. HTURKAK

    How is pressure under tank bottom plate distributed?

    How old are you ? If you keep being hungry to learn something new , you are a young engineer . Never be satisfied, and always push yourself. Your approach is excellent for gravity loads only. If the tank is located at high seismic zone , this will be another story. The bottom plate is...
  11. HTURKAK

    Checkered Plate On Metal Deck in Penthouse Floor

    I do not know if locally available at your zone ,but , i will suggest aluminium pop rivets . It will be cost effective and efficient . Moreover , effective for limiting the galvanic corrosion .
  12. HTURKAK

    Storage tank conversion from EFVRT to CRVT

    I do not see the reason for reducing the height . Just limit the filling height for the new requirements. Regarding the new cone roof, i agree with JSTEPHEN.
  13. HTURKAK

    Bulkheads for external floating roof

    API 650 is silent for the no. of compartments and radial bulkheads . In your case , i will suggest the followings acc. to my experience and understanding, - The no. of 19 bulkheads ( so 19 compartments ) is strange. I will expect an even figure and a reasonable radial angle . Pls count...
  14. HTURKAK

    Bulkheads for external floating roof

    What is the number of bulkheads at the outermost ring and how many inner rings are there ? Pls post some details ( at least a descriptive sketches showing the dia, no. of compartments at the outermost ring , and other rings ) to get better responds.
  15. HTURKAK

    Lifting a Precast beam 12 m length

    You will find the developing tension stresses and check with allowable tension stress .Assume uncracked section. The stresses during stripping , lifting and transport should be checked .
  16. HTURKAK

    Pinned Concrete Slab to Concrete Beam/Wall Connection

    We are very different time zones and i just see your respond . You can follow and adapt two way slab detailing rules or you may look ACI Detailing Manual. The following is excerpt form the manual .
  17. HTURKAK

    Bolt bearing - reduction for 'edge' distance in hollow sections (SHS/RHS) according to Eurocode?

    My understanding is , EN 1993-1-8 Table 3.4 Ab and k1 factors are for bearing failure mode. In your case , Clause 3.10.2 block tearing is applicable . The shear resistance of side wall could be added . My interpretation ..
  18. HTURKAK

    Pinned Concrete Slab to Concrete Beam/Wall Connection

    NO ! .. You are expected to provide at leat min . top reinf. If the slab supported on end beam ( the slab is not continuous ) . You can model simply supported although the beam will resist with torsion but will be negligible . If the side support is a wall , in this case the slab can be...
  19. HTURKAK

    Bolt bearing - reduction for 'edge' distance in hollow sections (SHS/RHS) according to Eurocode?

    EN 1993-1-8 Table 3.4 Ab and k1 factors are for bearing resistance and in your case AFAIK , you should use - Ab is the is the smallest of Ad ; fu/fub or 1,0 - for edge bolts: k1 is the smallest of ( 2,8 e2/d0 - 1,7 ) or 2,5 The following doc. gives a brief info. for bolted connections.
  20. HTURKAK

    Lifting a Precast beam 12 m length

    Yes.. but lift with overhangs at both sides say 2.5 m. Check tension stresses at span and lifting points. A preliminary calculation for allowable tension stress ( using 4 *SQRT* fc ) is 1.8 mPa . Check lateral stability also.