Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: kme
  • Order by date
  1. kme

    shear wall footing

    Check out Foundation Engineering Handbook by Joseph Bowles (excellent book). He has some formulas for checking overturning when you are outside the kern point
  2. kme

    Quality Assurance - Californian Building Permit Process

    Any California engineers out there? I was wondering if someone could describe to me the process a structural engineer goes through to obtain a building permit in California. It is my understanding that the Authority having Jurisdiction will complete an independant technical review of the...
  3. kme

    Foundation Design for Large Lateral Load

    What about a helical anchor pile such as a Chance anchor?
  4. kme

    Steel columns in 4 storey wood frame building - shrinkage issue

    You are correct, the columns are 40 ft tall. Thru each of the 2nd, 3rd and 4th floors, they will be laterally braced by the floor sheathing. However, it is not my intention to attach any of the lower floor levels to the steel columns in any fashion. Therefore I expect the problem will only be...
  5. kme

    two story townhouse

    We would normally do a masonry corbel.. i.e. and 8" block, then 10", then 12" (all grouted solid) and then bolt a 2x4 nailer to the top of the 12" block. For the second floor continue your 8" block on top of the 12" corbel. You will want to use a top chord bearing...
  6. kme

    Steel columns in 4 storey wood frame building - shrinkage issue

    Are you suggesting engineered wood products for all of my stud wall assemblies? The source of the shrinkage is on the top and bottom plates of the stud walls....
  7. kme

    Evaluation of ENERCALC5.5

    Has anybody ever tries Tedds (www.tedds.com)?
  8. kme

    Steel columns in 4 storey wood frame building - shrinkage issue

    I am working on a 4 storey multifamily wood frame building and have to put some steel columns from transfer slab elevation up to the roof to pick up some heavily loaded steel roof beams (Pf ~ 250 kips). The project is on a ski hill with roof snow load of 300 psf. The problem we have is that the...
  9. kme

    Superstructure-Pile Interaction considerations,any logic?

    Could you elimite the lateral issues on your piles with some batter piles? This may bring you a little more closer to a "rigid" foundation system (i.e. high natural frequency) where you may eliminate or greatly reduce any amplification effects from you pile system.
  10. kme

    concrete pour damaged by heavy rain

    I recently had the same problem but on a thin (3") structural slab (Hambro floor system) where it started raining on a 4000 s.f. pour. It continued to rain for most of the day so the finishers had a really tough time. The result is an extremely poor quality surface that has absolutely no...
Back
Top