Hello
Can anyone tell me if the zinc dross and zinc skimming ( resulted from galvanization ) consider to be hazardous waste according to basel convention ?
If there is recycling system for steel shot like this one for example:
https://www.youtube.com/watch?v=XX3DTuhy3qc
As you know the dust and small particles will be separated from the steel shot abrasive ( required size ) which will be reused.
Dust and unwanted particles will be stored in dust...
Hello..
If there is a company who do only aluminum extrusion( and not have anodizing plant ) , what is the best way to dispose sodium hydroxide solution waste resulted from cleaning the die ? Does reducing the PH by adding acid make the waste non hazardous ? Or additional steps is a must ???
I have question regarding the autoclave/vulcanizing the rubber rollers at temperature of 180 celsuis (using heat of steam only ) , the duration the rubber will be inside the autoclave is 4-6 hours .
Will be there any emissions resulting of autoclaving the rubber?
I have one tank with 5 m dia & dome roof.
Roof minimum thickness is 18 mm .
How I can reduce the thickness ? is it advisable to add rafters to reduce the thickness ?
I have one vessel 3.3 meter dia with welded heads and shell.
Client has specified that the vessel is spot radiographed . Also, they specifed the joint efficiency of heads is 1 and shell is 0.85.
What does it means ? Does it means that only A joint in the head will be fully radiographed ...
Hello
Why the thickness of the bottom course of tall columns has higher thickness than the rest? Is this because of liquid loads and how it is calculated?
Hello
I have two fixed roof tanks designed as per API 650 .
One is 3.5 m diameter and 4.5 m height .
Other one is 4.8 m diameter and 5 meter height .
Are stiffening rings / wind girders required in our case .
As per API 650 , Nominal thickness of roof plate shall not be less than the greater of D/(4.8*SIN PH)*ROOT(B/2.2)+CA, D/(5.5*SIN PH)*ROOT(U/2.2)+CA , 5 mm
My question if 5 mm is the greater shall we add the corrosion allowance ( CA ) so it will become 8 mm?
Hello
I have strange requirement from client . They ask for impact test for sa 106 gr.b. Pipe . MDMT is 25 F only . Ask per code is not required but it is additional requirement from client . Can we do the test in external lap?
I have underground tank with 0.8 m diameter and height 1.7 m . HLL is 1.4 m . Specific gravity of liquid is 1.2 . Internal pressure is Atm and static pressure of liquid . Roof is bolted cover .The design code is ASME sec Vlll dev .1 .
1) how I calculate the thickness of tank ( shell , bottom...
If we have a vessel with material of SA-516-60N and thickness 13 mm . Normally , after we do PWHT 6 hrs holding time and temperature 630 C . Will the material properties will be maintained as per the specification ?