  1. ARNAR

    HOW TO CHECK FOR TORSION

    @rb1957 : T/(1/3*b*t^2 gives what ?? any general formula for min thickness??
  2. ARNAR

    HOW TO CHECK FOR TORSION

    @WARose : The Bracket supported on the holes that doesn't have force on it (As you said) and loads are not equal (only in one leg and the other is very small or negligible). Any general formula for finding the stress or min thickness of the member ??
  3. ARNAR

    HOW TO CHECK FOR TORSION

    How to check the section (bracket fixed as shown below) for torsion ?? any general formula for min thickness??
  4. ARNAR

    Temperature load calculation code referance.

    Temperature change (range ) specified in project spec as 56 degree Celsius. They dint provide any other temperature data like( Ambient temperature , Max and Min temperature) Is this data sufficient for the temperature load calculation in staad pro ?? Any American code reference for temperature...
  5. ARNAR

    HOW TO MODEL 3mm THK HANGER WIRE in STAAD Pro V8i

    Hi guys, Please help me to find a solution. I'm using Staad V8i for strcural design. I wants to model hanger wire 3mm( Dia)Thk in staad.
  6. ARNAR

    REASON FOR MORE DEFLECTION ( SAME SUPPORT CONDITIONS, SPAN AND LOADING)

    @ Hokie66 : Ix is torsional constant of the section . Z Axis is horizontal and Y axis is vertical. IX = Torsional constant IY = Moment of inertia about y-axis.(vertical ) IZ = Moment of inertia about z-axis (Horizontal )
  7. ARNAR

    REASON FOR MORE DEFLECTION ( SAME SUPPORT CONDITIONS, SPAN AND LOADING)

    @ IFRS : The section properties are almost same in both cases. you can find in the attached filehttp://files.engineering.com/getfile.aspx?folder=08219bb2-73e9-404d-997d-37437b4a9aae&file=Fig.docx
  8. ARNAR

    REASON FOR MORE DEFLECTION ( SAME SUPPORT CONDITIONS, SPAN AND LOADING)

    PLEASE FIND THE ATTACHED FILE http://files.engineering.com/getfile.aspx?folder=18e827eb-8b02-4a59-b061-10100978f364&file=Fig.docx
  9. ARNAR

    REASON FOR MORE DEFLECTION ( SAME SUPPORT CONDITIONS, SPAN AND LOADING)

    Two beams with different sectional properties ( see the attached file. Fig 1 & fig 2 ) supported as simply supported at same span and same loading. While analyzing the section shown in fig 1 deflect more than Fig 2 . please help me to find a reason for that. What are the sectional properties...
  10. ARNAR

    Self drilling screws with minimum head size ( to fix inside 12mm groove )

    Please help me to find a SELF DRILLING screw to fix aluminium(3mm THK) to aluminium (3mm THK). The screw fixed inside a 12mm groove so we cant insert hexagonal socket .The Max Head size is 9-10mm Only and Pan head or Philips head preferred . Please suggest some world class screw manufacturers.
  11. ARNAR

    How to give impact load in STAAD Pro V8i

    @ warose what is formula in Blodgett's 'Design of Welded Structures' ??
  12. ARNAR

    How to give impact load in STAAD Pro V8i

    @ Klaus Thanks. but here panel is 0.6 mm thk steel with gypsum board backing.
  13. ARNAR

    How to give impact load in STAAD Pro V8i

    @ before that we need to check the system pass or not.
  14. ARNAR

    How to give impact load in STAAD Pro V8i

    @ WARose : Thanks for your advise. i want to check the partition wall system safe against the soft body impact test. In soft body impact test, hitting a softy body of mass 50kg with an energy of 300 joule. If i put the load quasi static load what impact factor i need to take ?? if i proceed with...
  15. ARNAR

    How to give impact load in STAAD Pro V8i

    How to give impact load in staad. i need to check the system will pass the soft body ( 300 joule) and hard body impact test as per the EOTA and ETAG 003. Whats the general procedure to convert the energy (joule or Nm ) to load ( to model in staad ) . Please help me to find a solution .
  16. ARNAR

    Wind load on External Hanging Ceiling

    Im designing a hanging ceiling for external use. I have to follow ASCE as per the project specification. But when i check the code (ASCE )no separate wind load calculation recommendation for Ceiling. If we consider it as components and cladding (C/C) All the hanging rods (M10) fails because of...
  17. ARNAR

    Live Loads consider for design of Partition walls in Office building

    @ RPMG @ dik @DETstru @ wannabe @anushka: Thank you so much for your suggestions and advice. I got a code reference for Internal non-load bearing partitions – DIN 4103-1
  18. ARNAR

    single bolted connection pinned and fixed ??

    @ hokie66: For find out reliable forces and deflection STAAD Pro V8i Used. @ Dhengr : Please find the attached model. Hangers channel size C-12x19 0.9THK mm Stabilizer size C- 14x38 1mm THK Bracing L-25x250.9mm. I took 1.0 DL + 1.0 EQ load and that one is the critical load @ Slickdeals ...
  19. ARNAR

    single bolted connection pinned and fixed ??

    I am designing steel framed structures to support ceilings. All the hangers are fixed with ceiling with expansion anchors. In staad model if we consider the connection as pinned it fails in deflection but all the utilization ratios are very small. how we can conclude whether it is pinned or...
  20. ARNAR

    Live Loads consider for design of Partition walls in Office building

    @MotorCity : Its not a cubicle wall ,its demount-able partition wall with book shelf.