Search results for query: *

  1. Abu najad

    Per pass conversion for second stage in the Hydrocraker unit

    How we can calculate per pass conversion in the Hydrocraker unit?
  2. Abu najad

    Volume of heat exchanger

    How I can calculate the volume of shell and tube heat exchanger?
  3. Abu najad

    Tank inventory calculation

    How I can calculate tank inventory for straight run gas oil, light Coker gas oil and Coker naphtha for DHT unit. Please can you give me example in excel sheet?
  4. Abu najad

    Heater Firing Control

    Which is the more accurate,not hunting and good for turning to control the firing on heater and why? 1.connecting temperature controller with fuel gas controller. 2.connecting temperature controller with low...
  5. Abu najad

    Reciprocating compressor pressure control

    Thanks a lot georgeverghese for your response on the topic. I could understand and feel the concept now.
  6. Abu najad

    Reciprocating compressor pressure control

    Thanks a lot Dear So I have to combine Sketch B and C.
  7. Abu najad

    Reciprocating compressor pressure control

    Thanks dear Appreciate your efforts to help me Tomorrow I am waiting for your sketch Please in your sketch you have to mention individual spillback for third stage and PC located at third stage suction.
  8. Abu najad

    Reciprocating compressor pressure control

    Thanks Dear I am so happy with your answers But there is protection controller for 3rd stage suction by individual spillback .
  9. Abu najad

    Reciprocating compressor pressure control

    Hi Dear, Thanks for your fast response Which I understand from sketch if PC20 pressure falls below set point output has to be increased and PV for PC10 also PV will come down because both PC10 and PC20 are taking PV from same line .So if PV for PC20 falls down same while PC10 which is...
  10. Abu najad

    Reciprocating compressor pressure control

    Hi georgeverghese I agree with you PC100B should be reverse action and PC225 should be Direct acting.And what about PC100A and PC200 which one is must be Direct action ? Because PC200 set point is output of recycle gas compressor suction (Hydrocraker system pressure PC305) For example if...
  11. Abu najad

    Reciprocating compressor pressure control

    Dear georgeverghese There is to pressure controller located at make up gas compressor KOD drum .PC100A set with low set point and PC100B set with low low set point . If the first stage compressor suction pressure falls too low, suction line pressure controller PC100A will open the common...
  12. Abu najad

    Reciprocating compressor pressure control

    We have three make gas compressor reciprocating type Three stages .it has individual and common spillback we are supplying hydrogen to Hydrocraker from last stage and from second stage to DHT .which is better to to control pressure for both low selector or high selector with spillback and...
  13. Abu najad

    Heaters refractory dry out

    I want guidelines for heaters dry out.How much temperature should be in firebox ?we can do dry out with media (steam,nitrogen and oil) or with out and why?
  14. Abu najad

    Reciprocating compressor pressure control

    We have make up gas compressor reciprocating with three stages and three trains.suction pressure 22 bar and discharge pressure 185 bar It has common and individual spillback.second stage is fed to diesel unit. What is the purpose of individual spillback and how we can control the pressure to...