thank you for your concern and all tube thickness already checked and were accepted ,the issue is because the bundle is under ASME inspection AND they need evidences from code and i didnt find any at any codes telling what is the acceptance ratio for R=1D ,thank you
DEARS
I HAVE U TUBES FOR HEAT EXCHANGER WITH MORE DIFFERENT BEND RADIUS ,ALL MEASURED OVALITY(FLATNESS) FOR ALL KIND OF BEND RADIUS WAS IN TOLERANCE EXCEPT THAT RADIUS= 1 O.D. THE OVALITY MEASURES 14% WHICH IS OUT OF TOLERANCE AS PER TEMA (10%) IS THERE ANY STANDARD FOR U TUBES WITH R=1D AND...
Dear Sir,