Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. MatMan83

    EN 13480-3 wall thickness calc material properties.

    Hi, I have a question regarding EN13480-3 wall thickness calc and the elevated temperature properties of materials when they are not listed in the specifications. For example, P265GH and P265NL - P265GH has elevated temperature properties stated in EN 10216-2, whilst P265NL only has material...
  2. MatMan83

    EN13480 WT calc when elevated temp proof strength of materials is not listed.

    Hi, I have a question regarding EN13480 wall thickness calcs and the elevated temperature of materials when they are not explicitly stated in the specifications. For example, P265GH and P265NL - P265GH has tabulated values for proof strength at elevated temperatures (RP0.2,t) in EN10216-2...
  3. MatMan83

    Pump nozzle overloaded due to solar gain of piping.

    Hi all. I have an issue with a pipe getting too hot in the sun. The line in question is a DN1600 CS pipe which is connected to a piece of rotating equipment. The normal operating temp for the line is 36degC and under normal conditions it will be full of flowing water. However, during major...

Part and Inventory Search