We typically use the following criteria (against the Ag/AgCl/seawater reference electrode):
1. Under-protected: potentials more positive than -800mV
2. Low protection: potentials between -800mV and -900mV
3. Adequate protection: potentials between -900mV and -950mV
4. Good protection...