  1. Pjstol

    Delegated Design of Steel Joist to Joist Girder Connection

    A joist manufacturer on the west coast is refusing to design these connections. They claim they can't do it because of code (even though a joist manufacturer will design these connections on the east coast). so is it mandatory for the EOR to design these? if the joist contractor won't do it...
  2. Pjstol

    Submittal Revision - Comparison between Steel Shop Model (Tekla) and Design Model (Revit)

    How do your offices typically aproach the revision of submittals for structural steel? Is there am efficient way to make sure fabricator matches design intent? (anything that would be faster than checking each drawings, element by element, to see if information in both match) Thanks!
  3. Pjstol

    Minimum Distance between Bottom of Anchor Rod and Bottom of Footing

    Checking ACI 314-16, it doesn't really make it clear which edge min distance is referring to 17.7.2 Unless determined in accordance with 17.7.4, minimum edge distances for cast-in anchors that will not be torqued shall be based on specified cover requirements for reinforcement in 20.6.1. For...
  4. Pjstol

    Minimum Distance between Bottom of Anchor Rod and Bottom of Footing

    Tried to find the answer in AISC design guide 1 but can't find any number. Any references?? Thanks!
  5. Pjstol

    Elevator/Vertical Lift - Story Drift Accomodation

    what would people do in these cases then? Just expect the elevator to somehow fail and repair the damage after the event?
  6. Pjstol

    Elevator/Vertical Lift - Story Drift Accomodation

    Thanks for your answer!. Say story drift is max allowed by 12.12-1 for a 25 ft story height.. so 7.5 in of drift. It would only make sense that elevator vendor would design for allowable drift, right??
  7. Pjstol

    Elevator/Vertical Lift - Story Drift Accomodation

    say you have a 2 story building with an elevator in it. to design the elevator, vendor doesn't take into account the story drift due to lateral loads. they brace their rails to the supporting structure and only provide those reactions. What is the proper way to account for story drift in an...
  8. Pjstol

    Drilled Pier without Pile Cap

    Is there any requirement to have the pile cap on top of pier or can this be avoided? Thanks
  9. Pjstol

    Avoiding Tie Beam Requirement

    If soil around shallow footings has been improved, do you still need to tie shallow foootings being in SDC D, E or F, Site Class E or F. Thanks
  10. Pjstol

    Seismic Compliance of Electrical Panels

    So I have 3 vendors offering panels that are compliant with "Seismic Zone 4 (0.5g)". I'm not familiar with this rating provided or used by electricians. I would expect that rating to be in compliance/meets ASCE 7 Cs or Sds=some-high-value Any previous experience with something alike here? Thanks!