  1. JRS45

    A325 Bolt Shear Strength

    According to the ASTM, A325 bolts come in two minimum tensile strengths: 120 ksi for 1" diameter and below, and 105 ksi for anything over 1" diameter. Yet the steel construction manual Table 7-1 gives the same Fnv value regardless of bolt diameter. If I understand correctly, Fnv=0.45Fu...