Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. engr.levy

    Minimum Shear reinforcement for Short Piles

    How about Vu>Vc but the Vs shear requirement is less than the minimum shear formula? The Vs only requires 12-200mm ties but the minimum shear formula requires 16-200 (due to large diameter of pile) I am just not sure if we are required to satisfy the minimum formula for columns or piles.
  2. engr.levy

    Minimum Shear reinforcement for Short Piles

    I had a discussion with my supervisor regarding the minimum shear reinforcement for piles. This case our pile was a short pile with bid diameter and the lateral loads governing. I am just confused on the shear reinforcement as I am designing the reinforcement for the actual Vs requirement...
  3. engr.levy

    O-Calc Pro Pole Modelling Software

    Anybody here has experience with O-Calc Pro Software? It is made by a utility company in US named Osmose. I was hired by their subsidiary in Australia and will start next month so I want to get an idea of the software. I have background in PLS Pole and PLS CADD before but not that much.
  4. engr.levy

    Canadian P.Eng Interested in being a Mentor/Sponsor for BCIT Student Project

    Hi Mates, I am helping a friend that is looking for a sponsor for her project study this coming semester in BCIT. She needs someone in Canada, preferably in BC, with a P.Eng designation to act as a mentor on her project. The role is more of giving technical guidance, review, and input on the...
  5. engr.levy

    Harmonic Filter Foundation

    Does this equipment has rotors or produce vibrations that will affect the foundation? And how to design the foundation for that?
  6. engr.levy

    ASCE 113 Equivalent to AU/NZ

    Retrograde (Structural)3 Apr 19 04:24 Some of the individual utility companies have their own design guides: https://www.transgrid.com.au/what-we-do/our-networ... https://www.ergon.com.au/__data/assets/pdf_file/00... Thanks for the reply. Will check this out. Do substation foundation designed...
  7. engr.levy

    ASCE 113 Equivalent to AU/NZ

    Is there an Australian standard/guide equivalent to ASCE 113?
  8. engr.levy

    ASCE 113 Equivalent to Australia

    I will be designing a substation here in Sydney and I am looking for a design guide like ASCE 113.
  9. engr.levy

    Difference of AISC(Australian) to AISC(US) - For STAAD Connection design

    Hi, Is there any major difference in the Australian steel codes vs the US codes? I know some of the basis of the Au codes are also from AISC guidelines. I am planning to utilize the STAAD.Pro Connect Edition's connection design and it doesn't have a built in Australian code for the connections.
  10. engr.levy

    Column Design Software for ANZ codes

    Hi, Anyone knows a column design software like SPCol and CSICol for Australian market? Both did not support Australian code. Thanks.

Part and Inventory Search