Hello friends , thank you very much for your responses.
Now , with respect to the Nitrogen generator. I finally think it will not cover the 151 CFM with 145 psig.
First , I would like to clarify the issue of the units.
In Table 4.2 the units are Nm3/h , but here "N" doesnt refer to normal...
Hello friends , I work for a engineering company in Perú.
I want to get the air flow required by a nitrogen generator .
I have the flow of nitrogen .
Q = 71.52 L/s = 151.54 CFM
Pressure = 145 psig
The site conditions of the project are :
P atm = 56 kPa
T average = 7°C
But , the mining...