@r6155 :
The exact location of C.G. is needed for shipping and lifting calculation due to the client's request.
@SnTMan: Thanks. I have checked Dennis Moss and it has been discussed there.
I might be brought up my question wrongly. But the question is exactly what "Christine74" said.
In PV elite, shows the distance of C.G. in only one direction. For the other direction (elevation of C.G. from horizontal centerline) is any know how to do?
Dear All
I want to calculate the center of gravity location on a horizontal vessel. When I perform mechanical calculations, the PV Elite software shows the location of C.G. in one direction (From Left T.L.).
But the offset of C.G. from the centerline is a question for me. The question is:
"How...
Dear All; Thanks for your answers.
The design Code is ASME SEC. VIII-D1. I know how to calculate the test pressure according to UG-99. But the question is "What is the allowable stress for the hydrostatic test?"
According to the SEC. VIII, the maximum allowable stress for the hydro test is 90%...
Dear All
I have a qouestion:
In hydrostatic test calculation, what is the allowable stress reference when considering not 90% of the yield stress?
I checked. It is 1.3 times the allowable stress data that is mentioned in Sec.II-D. But I wanted the reference for it.
Can anybody help me...
Dear All
I modeled a tower in PV Elite. For wind calculation according to ASCE 2010, I can't change the importance factor and the value is 1. I searched ASCE 7-10 and according to different categories and also according to the site condition the importance factor is 1.15 in my case. Does anyone...