Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. jtylerb72

    Looking for assistance with vacuum insulation of a cryogenic storage vessel and VJ piping

    georgeverghese and Ed, I am familiar with cold boxes and their nitrogen purge. The major difference between that application and a bulk tank is that the inner vessel is designed to withstand outward pressure, not inward pressure. So to purge the perlite, or the annular space in general, you...
  2. jtylerb72

    Looking for assistance with vacuum insulation of a cryogenic storage vessel and VJ piping

    I completely agree with the MLI and perlite comments. We keep the MLI in a heated storage fridge. We use a line heater and a vacuum pump to dry out the MLI upon installation. We get things dry and ready to ship in about five days now. We have made some progress here. Most of the bulk tanks we...
  3. jtylerb72

    Looking for assistance with vacuum insulation of a cryogenic storage vessel and VJ piping

    I work with ASME Section 8 cryogenic storage tanks. I am interested in finding some folks to converse with about vacuum insulation between the inner and outer vessel of a cryogenic storage tank. These tanks would be insulated with either MLI and vacuum or perlite and vacuum. I am interested in...
Back