  1. JBNKL

    Test pressure of PN flanges x 1.5 design pressure...........where does this come from???

    Hi Huub, We did a little more digging today, below is from an email summary: [u]ASME B31.3-2016 Process Piping Section 345.4.2 Test Pressure, page 124 Except as provided in para. 345.4.3, the hydrostatic test pressure at every point in the metallic piping system shall be a follows: (a) Not...
  2. JBNKL

    Test pressure of PN flanges x 1.5 design pressure...........where does this come from???

    I have a question on design pressure of PN flanges and test pressure. My understanding is that a PN10 flange can take 10barg design pressure, and that you can test the flanged pipe to 1.5 x the design pressure. PN10 flanged pipe can take up to 15barg test pressure. Similar for PN16 flanges they...