I'm working on a 4 bolted assembly in ANSYS and modeling my fasteners using bushings with stiffness values. Thinking about this from a design/fit up perspective, one of the holes will be shear carrying and used for clocking the part. Does that mean I should assume the other 3 fasteners are nmot...