Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations GregLocock on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Zeecloud

    SA516-70 Heat Treatment Condition Marking Requirements

    Thank you all for your help and support. Things are clear to me now.
  2. Zeecloud

    SA516-70 Heat Treatment Condition Marking Requirements

    In the test report it states “ Normalizing Rolling for below & Including 40 mm Thk Plate” it also mentions “Furnace Normalized for above 40 mm Thk Plate Supply Condition: Furnace Normalized at 900 ± 20°C, cycle time minimum: 1.4 minutes per mm thickness + 10 minutes” So it’s not normalized but...
  3. Zeecloud

    SA516-70 Heat Treatment Condition Marking Requirements

    Thank you for your reply folks. Honestly I come from an Electrical background and all this is new to me so just for me to know what I am talking about before approaching the AI, as rolled means it’s not heat treated. If thickness is less than required to be normalized (heat treated), then there...
  4. Zeecloud

    SA516-70 Heat Treatment Condition Marking Requirements

    “MT” is not marked anywhere on the plate. 2013 SECTION II, PART A in SA-516/SA-516M Para 5 it states that “ Plates 1.50 in. [40 mm] and under in thickness are normally supplied in the as-rolled condition.” could this be the reason?
  5. Zeecloud

    SA516-70 Heat Treatment Condition Marking Requirements

    Hello All, We have purchased an SA516-70 plate. I am a little bit concerned because heat treatment condition is not marked on the plate, should this raise any issues? Or is it okay? I have attached a picture of the marking. Thank you...