I believe ASME VIII-1 UG-125 thru UG-136 will also tell me what I need. If anyone knows where I can view a free copy of this, it would be greatly appreciated.
Does anyone have an SMP they can share that allows for changing conservation vents on Methanol tanks WITHOUT having to de-inventory the tank? We have a 250000 gal. MEOH tank that needs the vent changed out, but corporate engineering is trying to make us de-inventory the entire tank before we can...
I recently located to Arkansas from Louisiana (non-code state) where we had flexibility in this situation to conduct a Fit-for Service that would allow us to re-calcualte all of the mechanical calculations based on current full internal inspection results and current process specifications. A...
We have an older heat exchanger that is missing its ASME nameplate and U1 form. The original drawing is also very generic and has no traceability reference data listed. It is my understanding that my only course of action here is to perform a complete Fit for Service evaluation (including...