Hi Littleinch, 1503-44 and Artisi. Thank you for your time and for the advice, highly appreciate them. This is my first thread as new comer to this forum and I feel so lucky to have your good advice gentlemen.
I never had a chance to visit the power plant, nor get adequate information from them...
There are 4 units of circulating water pumps (BB1 type) of same size. They operate at 1500m3/h with head of 30m each. I think there are 2 standby pumps. New pump will be operated at 3000m3/h with head of 30m. The plant is 2x7MW (CFPP). Please see drawing from the link.
I do not have data about...