Hi LittleInch and MJCronin, I appreciate your inputs..
For info, the header is connected to a surge tank which have another pipe to discharge the water.
The flow rate of each pump is the same which is 2 cubic meter per second.
Yes, I don't have enough knowledge on this because Im new at my...
The pumps will be used at the pumping station, it can run one pump at a time or 2 pumps or 3 pumps all at the same time, depends on the level of floodwater.
The header will only act as a discharge pipe of the 3 pipes, regardless of velocity and pressure.. the only purpose of the header is to...
I think you misunderstood that the water flows from header and it will branch outflow to 3 pipes..
This is the set-up Sir,
I have 3 water pumps with 3 discharge pipes of 1200mm inside diameter each going to 1 header (no pipe size yet), can I use the area method to calculate the header?
I...
Hi 1503-44, thank you for answering my question.
However, can you analyze this drawing I have.. 3 pipes going to a header. please disregard the assumed size of...
thread378-341586
Hi Everyone,
I have 3 pipes with the same ID of 1200mm, and I need to design a header pipe for these three pipes.
Can anyone show me how to compute or design the needed header?
Your inputs will be highly appreciated.
Thanks!