Thank you weldstan, We performed Brinell Hardness Tests on the unheated pipe, heated pipe, weld cap, and valve. All indications are that there was no change in hardness of the base materials and we have elected to follow your first recommendation.
As the saying goes - Long time reader - first time poster.