  1. EEENGRX

    GROUNDING AND BONDING OF RAIL ROAD TRACKS

    This is within a plant environment for Tank Car loading rack grounding. Ie the Portion normally occupied by cars to be insulated from main tracks. And all rails in the insulated section to be bonded together. This is per bonded to loading arms and loading rack structure and grounded or...
  2. EEENGRX

    GROUNDING AND BONDING OF RAIL ROAD TRACKS

    What are the relevant standards for grounding and bonding of Rail Road tracks ?I know Article 250 per NFPA talks about grounding and bonding but i am looking for very specific information on the applicable standards in this case?
  3. EEENGRX

    Two instrumemts, Same Loop

    I have an existing Radar Level transmitter on a Tank with a HART protocol. I want to hook up a pressure transmitter to same tank but on the already existing loop. what is the best way to run thisn connection as i think thisnis possible since they have same HART protocol.I need very clear ways...
  4. EEENGRX

    Sporadic pump Trip

    What other ways can you think of?
  5. EEENGRX

    Sporadic pump Trip

    It uses a Float switch.. The waves in the sump make it stop and start. I am thinking of putting a pneumatic time delay relay. Let me know what you think and any other ideas you think could work better
  6. EEENGRX

    Sporadic pump Trip

    I have a pump that is sporadically starting and stopping when the level in the sump gets low. What do you think might be a good solution to this issue
  7. EEENGRX

    Pressure switch

    For a pressure switch that is connected to a rupture disk which also has a PSV. Is it advisable to have the same set point with that of the PSV or a little lower?
  8. EEENGRX

    Valve Stem twisting

    I will gather more details are get back to you. and possibly pictures
  9. EEENGRX

    Valve Stem twisting

    yes sure
  10. EEENGRX

    Valve Stem twisting

    Yes isolation valves
  11. EEENGRX

    Valve Stem twisting

    What do you think about the actuator response time? what if the response time was slowed down?
  12. EEENGRX

    Valve Stem twisting

    Oh yes, when the ambient is cold, sending pressure down to actuate the valves typically results in the stems getting twisted and damaged. This could be due to the sudden response of the valves after the very low temperature
  13. EEENGRX

    Valve Stem twisting

    What are some of the options or solutions to consider if its possible to restric airflow to a few valves that are thawing out to to avoid twisting the stems. Any ideas will be very welcome. Most of these valves have actuators with Air/Air Actuators with a speed of 1''/sec and have a size range...
  14. EEENGRX

    Tie feeder breaker connection

    Due to PDC-2 not having an emergency Generator and its consequence when there is loss of power from the main grid. The need to implement a Tie feeder breaker between PDC-1 and PDC 2 and run cables. This is to enable power supply to the UPS fed from PDC-2 without having to depend or use...
  15. EEENGRX

    Installation of float and pressure switch for motor control

    Oh thanks. I think I misunderstood part of your explanation. I will be putting it between the start and stop bottoms and like you said . It’s the simplest circuit there. That way I can still retain manual control and also have automatic control for emergency shut down on low oil level and low...
  16. EEENGRX

    Installation of float and pressure switch for motor control

    Check out the most recent image I attached. I have four options in there
  17. EEENGRX

    Installation of float and pressure switch for motor control

    Okay what do you think about lacing in series between START PM-2605-2 and STOP PM2505-1. I am Looking at preserving the Manual control functionality and also having automatic control. The float switch is SPDT and it’s NO Let me know what you think
  18. EEENGRX

    Installation of float and pressure switch for motor control

    I intend to connect the low level float switch and the pressure switch in series.Are you suggesting not wiring them in series with each other?see both suggestions I have in the attached marked-up sheet and let me know what you think.This is because I want to attach a seal pot to the pump and I...
  19. EEENGRX

    Boiler steam control

    I have a Specialty Chemical boiler DA tank whose pressure/temperature control valve is not functioning correctly and subsequently the DA tank is feeding water to the boiler that hasn’t been preheated properly. After troubleshooting it was recommended changing the valve.A new one was installed...