Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. remlap

    Intrinsically Safe CAN J1939 ??

    Hi all, Does anyone have any experience using SAE J1939 on intrinsically safe equipment, e.g. for underground mining? Some have suggested that its near impossible to get J1939 IS certified, but I know that a lot of mining equipment use it... What's the solution? Thanks, Ray
  2. remlap

    Which resonant point is more dangerous?

    Thanks Greg, Yes, accelerations. The application is a 40kg resistor assembly mounted on a locomotive. Our customer's spec says to test using a constant G sweep, and then 8hrs at the resonant point. My supplier just chose the low F point, but I thought (without knowing the mech theory of...
  3. remlap

    Which resonant point is more dangerous?

    Hi! Sorry, another fundamental mech question from an elec eng, but you guys are just SO helpful!! If I have a sinusoidal sweep results graph that shows a 10dB resonance at 35Hz and another 10dB resonance at 250Hz, at which frequency should I do my sinusoidal endurance test? Thanks. Ray (Japan)
  4. remlap

    Vibration Mounts: Nat. freq. Vs Displacement

    This question is from an electrical engineer, so I apologise is I'm missing some fundamental knowledge... 1. Given a graph of "force vs displacement" for a particular anti-vibration mount, is it possible to determine its natural frequency? 2. If two mounts have similar "force vs...
Back