@r6155
Sorry for the late reply I got caught up in something.
It's a horizontal vessel intended for oxygen treatment as @DriveMeNuts have mentioned. I mentioned most of the design inputs in a previous reply but I can sum them up for you.
Design conditions: 4.5 bars @90°C
Material: SA-516 gr...
@drivemenuts
I also think that red line looks weird and will definitely consider not running it through the weld. I just think that technically any nozzle in a formed head that has an inside projection and welded on both sides should -especially if it's a hill side nozzle- face the same issue...
Thank you for your kind & quick response,
What exactly do you mean by "run through the weld"? do you mean like the red or the yellow lines in the attached photo? or do you mean something else?
The toe of the fillet weld at the door's corner does not intrude in the knuckle but it's some what...
Dears;