I'm working on the explicit simulation of needle insertion into a thermoplastic polyurethane foil (0.4mm thick) using a cohesive (orphan mesh elements) zone modeled between two parts of a phantom corresponding to the outer diameter of the needle tip. While using an intricate bevel needle, the...
What would be the reasonable range of strain to consider for the evaluation? I have to check for other hyperelastic models.
I considered surface-based cohesive behavior as it is computationally less expensive than cohesive elements. Would it be better to model using cohesive elements?
Yes, I tried using material evaluation in Abaqus CAE, which shows that it is stable for all strains. But I can see a warning which states that the hyperelastic material is unstable in the .dat file.
I'm working on the simulation of needle penetration into a thermoplastic polyurethane foil (0.4mm thick) using cohesive interaction behavior between two parts of a phantom corresponding to the outer diameter of the cutting edges of the needle tip. As for the model, I'm using a symmetric model by...
Hello,
I am running a quasi-static analysis of medical needle penetration into a thermoplastic polyurethane material (0.4mm thick) using cohesive zone modeling in Abaqus Explicit solver.