  1. KangCy

    Improving cooling jacket efficiency

    Latexman, if we agitate faster, we will add more heat to the system right? Do you think it will solve this issue? Because the solution is anyway non viscous.
  2. KangCy

    Improving cooling jacket efficiency

    What do you mean by pumping upward?
  3. KangCy

    Improving cooling jacket efficiency

    How is the mixing looking like from the video?https://www.veed.io/view/59aeba8a-8a1d-4633-8916-5a877c39cabe?sharingWidget=true
  4. KangCy

    Improving cooling jacket efficiency

    Changes to equipment is not possible due to budget. And pilot plant test is coming up soon. That's why change needs to be in process conditions.
  5. KangCy

    Improving cooling jacket efficiency

    Based on the actual experimental data, U-value is at 41 W/m2 K. Is this reasonable for a cooling jacket?
  6. KangCy

    Improving cooling jacket efficiency

    This is the cooling rate profile. The duty decreases as temperature decreases and probably is due to loss of thermal coefficient on the wall. However, at over 0oC we can still see that the cooling duty is quite low compared to chiller duty of 10kW.
  7. KangCy

    Improving cooling jacket efficiency

    Compositepro, will this work also if the tank will be used for crystallization purposes?
  8. KangCy

    Improving cooling jacket efficiency

    The jacket is plain, there are no cooling tubes. Drawing of the jacket is not available.
  9. KangCy

    Improving cooling jacket efficiency

    LittleInch, My inlet and outlet temp of the cooling circuit is almost the same. No difference which I can't say a number due to error of instruments. I would like to keep the reaction below 5-6 oC with a coolant that will be at -20oC. The temperature outlet with content temperature has a...
  10. KangCy

    Improving cooling jacket efficiency

    Hello, I have a mixing tank 1.7 m3 half covered with plain cooling jacket (heat transfer area 2.44 m2). I tend to use the mixing tank for a reaction that is exothermic (ca -10kW), for that reason I want to check if cooling duty of chiller and jacket is sufficient. We carried out some tests...