All,
I been reading conflicting information on the questions below as well as finding different answers online:
1. Will there be issues with inspecting a finned tube (Adm brass tube with aluminum fins) with ET? Will there be interference issues?
2. Does ET or IRIS give false readings at...
@1503-44
This is a lot of good information you provided. I will bookmark this page as I know i will be revisiting this information again.
Thanks again!
Thank you 1503-44 i appreciate this wealth of info.
My last question has to do with condensate.
B31.4 section 400a states that pipelines transporting condensate can be included.
Your responses seem to indicate that only oil is considered for B31.4. Am I missing understanding you?
Thank you everyone for the input
@1503-44:
"If you are not doing any separation at the well sites themselves, basically running the well stream of some combination of gas, oil and water straight to the processing facility, its not a B31.4 pipeline, its all basically a production pipeline, so...
Hello,
I work at a gas treating facility. We have production wells as well as the actually treating facilities.
We are looking at installing some piping for an upcoming project and we would like to ensure we are using the correct B31 code.
There are 2 lines we are interested in constructing...