Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Gforce08

    Fully configurable Logic

    For those of you who have utilized reclosers and various control platforms they can be paired them with- what exactly is configurable logic? How have you taken advantage of it? Is it worth it? I saw this feature show up on a chart with various recloser controls and figured I'd gauge the forum's...
  2. Gforce08

    Air Core Reactors

    I was recently introduced to this company by a colleague and am curious if anyone has a success story implementing the air core reactors found here: https://www.phoenixeleccorp.com/products/air-core-reactors/ Let me know what your opinion is on using Pheonix or air core reactors in general, please.
  3. Gforce08

    800/900 AMP Fault interruption, fault isolation, and circuit restoration

    A document attached supporting the use of regowski coils. There is more where this came from. Because Rogowski coils have much smaller power loss than conventional CTs, they provide excellent energy savings and reduced lifecycle costs. Rogowski Coils can easily replace conventional CTs for...
  4. Gforce08

    800/900 AMP Fault interruption, fault isolation, and circuit restoration

    These were from a course completed yesterday put on by an engineering group. You're right about how any brand can balance the load between substations.; Most manufacturers of reclosers controls can enable sectionalizer features as well. The above images are some examples of how the IntelliRupter...
  5. Gforce08

    800/900 AMP Fault interruption, fault isolation, and circuit restoration

    I was told yesterday the IntelliRupter helps balance the load among substations; the unit uses Rogowski coil sensors instead of CTs. Because Rogowski coils have much smaller power loss than conventional CTs, they provide excellent energy savings and reduced lifecycle costs. What other devices...
  6. Gforce08

    800/900 AMP Fault interruption, fault isolation, and circuit restoration

    Cool, thanks for the info. What type of applications has anyone used the intellirupter for? Is it worth it as opposed to other Reclosers on the market?
  7. Gforce08

    800/900 AMP Fault interruption, fault isolation, and circuit restoration

    At 15.5kv S&C's IntelliRupter is rated at 16000 Short-circuit breaking and symmetrical. Has anyone figured out the best application or how to utilize S&Cs IntelliRupter? If used before, how well does it coordinate?

Part and Inventory Search