Thanks for your kindly replies, we have solved the problem. The problem ıs our return line valve was broken and we didn't know that today we observed it and when we change the valve the problem solved.
There are spring bolts on these furnaces other connections. The vendor send us the dimensıons of tightening but for that bolts which has leakage no information, no dimensions thats why we are facing with that problem.
Hi everyone, we have a hidrocloric acid furnace, this furnace has 3 part and every part connected each other with flanges. We are running that furnace for 15 months and furnace temperature between 250-400 C(varies according to load) this furnace has leakage from the flanges connections. When we...
We have solved problem. We close the return lıne valve to %10 and the sound has cut. Our operation point has moved to right and we adjusted it. Thanks for your replies.
I have centrifugal pumps ın my company. We are usıng for transfer cooling tower water. these pumps are parallel. when we run only one pump ıt ıs creating noise like cavitation but we run other pump same time the noise is cut off. I dont want to run these pumps same time, one of must be spare...