Currentely, I'm using "MODELOPT CONC FLAT ELEV BETA" in the aermod.inp. My sfc and pfl files are generated from WRF (using MMIF). I'd like to model the PM10 and PM2.5 in AERMOD. However, when I did tests (using the same emission rate) I got the same values both PM10 and PM2.5. I think could be...
Hi everyone,
I would like to know if it is possible to run with more than one pollutant in the AERMOD. Can you add more than one pollutant in the POLLUTID keyword from aermod.inp, perhaps separated by a space?
Hello, everyone, I would want to know how many vertical layers is recommended to use in the Meterological Profile file (PFL) to be used on AERMOD?
Maybe only two levels (2 and 10 meters) or should be more?