Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Eng.V-C

    Masonry filled cells with rebar above and below window openings (Florida Residential Construction)

    Is it neccesary to have masonry filled cells with rebar above and below window openings? Is there any code requirement for that ? I see some builders add them and some don't.
  2. Eng.V-C

    Florida Residential Slab Control Joints and Corner Bars

    For Florida Residential Buildings(1 and 2 Story houses): 1- Do you guys put corner bars intersecting Slab Control Joints at corners? Or we should only use one of the two, either control joint or corner bar, because one could defeat the purpose of having the other? See Snip below 2- Do you guys...
  3. Eng.V-C

    Florida Residential Slab Control Joints and Corner Bars

    For Florida Residential Buildings(1 and 2 Story houses): 1- Do you guys put corner bars intersecting Slab Control Joints at corners? Or we should only use one of the two, either control joint or corner bar, because one defeats the purpose of having the other. See Snip below 2- Do you guys add...
  4. Eng.V-C

    Residential Slab on grade Epoxy rebar connection

    Thank you all for your contributions.
  5. Eng.V-C

    Residential Slab on grade Epoxy rebar connection

    I am the structural engineer in charge of providing this detail. The snip of the one I attached is an example I was provided with from another firm and I just wanted to know if it meets the code requirements. I just wanted to know if there is a code for this type of connection or a design...
  6. Eng.V-C

    Residential Slab on grade Epoxy rebar connection

    How do you design it? What Engineering Principles? Do you have an example?
  7. Eng.V-C

    Residential Slab on grade Epoxy rebar connection

    Thank you for your responses. This for a garage extension of a 1 story CMU house. Is there any section of the ACI360 that you can guide me to? ... I have been looking for a requirement or guidelines there and I have not found anything specific for my condition. So there is not a Code that...
  8. Eng.V-C

    Residential Slab on grade Epoxy rebar connection

    Does Anyone know what is the min. code requirement for rebar length into new slab when connecting existing slab to new slab with epoxied rebars? And how about max. spacing? ACI318 calls for 18" max. spacing for temp and shrinkage reinf. ... Is that applicable for nonstructural slabs on ground...
  9. Eng.V-C

    Monolithic footing with fiber mesh (In Florida)

    XR250, Would you mind sharing the spreadsheet that you used to balance the footing eccentricity? Which section of the IRC are you referring to?
  10. Eng.V-C

    Monolithic footing with fiber mesh (In Florida)

    Thank you for your responses DaveAtkins and phamENG. How can you account for load eccentricity using the approach #2. When you spread the load at 45 deg?
  11. Eng.V-C

    Monolithic footing with fiber mesh (In Florida)

    In Residential Construction in Florida, A lot of houses (1 and 2 story)are designed with Monolithic Footing with fiber mesh on top. I have read multiple forums and re-searched online and asked around in my office and I have not found calculations for monolithic footings with fiber mesh on top...

Part and Inventory Search