GD2,
Thank you for your valuable reply.
Actually while selecting nozzle material in PV elite, there is not any option to select the curve A, curve B, C or D. It only takes material input. Kindly guide me if there is any such option.
Apart from that, I have...
dig1,
Thank you for your guidance. is MDMT a user input ? or we are supposed to take it from Sec II part d ?
I had written 28.9 Deg celcius as it is MDMT for SA 516 gr 70 as per SEC II part D.
is MDMT depend upon the surroundings of Pressure vessel or location where vessel will be working ?
Dear Community members,
currently, I'm designing a pressure vessel 6 mm thk, with 1400 mm long shell having OD of 500 mm. I'm getting a warning in PV elite report which says, Computed overall MDMT was higher than the required value !
, could you please guide me to resolve it ?. I'm not...