Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: rw5
  • Order by date
  1. rw5

    mass scaling problem

    It still shows the smaller one. Only scaling the whole model by a factor works.
  2. rw5

    mass scaling problem

    Yeah, I've used the verify mesh tool to create a set containing the elements with low stable time (PoorElements-set in the Edit Mass Scaling dialog window - see snip above).
  3. rw5

    mass scaling problem

    There aren't any warning messages related to mass scaling. I've tried scaling the whole model by a factor (100) and the stable time incr is now 2,72e-06. But I'm not sure whether applying the mass scaling on all elements is suitable for my model since I only wanted to apply it to finite elements...
  4. rw5

    mass scaling problem

    hi, I'm modeling a cyclic loaded masonry wall in abaqus explicit. Since the model is relatively large, I've tried to use mass scaling to slightly adjust the stable time increment and reduce the computation time. I have an initial step + 4 additional steps, and I've assigned mass scaling in the...
  5. rw5

    abaqus cohesive contact respose warning explanation

    I'll try to do the calculation with the modified viscosity coefficient but I'll also try the dynamic analysis. I have several testing specimens and expect relatively large displacements so I think the dynamic analysis could be more suitable. Can you please tell me, is dynamic explicit analysis...
  6. rw5

    abaqus cohesive contact respose warning explanation

    yeah,I've already assigned the viscosity coefficient (=0.002). I can try to increase the value of the coefficient. Do you have any advice on choosing the values of the viscosity coefficient? If I understood correctly, it's related to the size of the time increment..
  7. rw5

    abaqus cohesive contact respose warning explanation

    Error message: Too many attempts made for this increment The analysis has been terminated due to previous errors. All output requests have been written for the last converged increment. Abaqus/Standard Analysis exited with an error - Please see the message file for possible error messages if...
  8. rw5

    abaqus cohesive contact respose warning explanation

    hi, im modeling a cyclic loaded masonry wall in abaqus. I keep getting warnings such as: COHESIVE CONTACT RESPOSE IS COMPUTED AT SLAVE NODE 24 INSTANCE OPEKA-2-LIN-2-1-1-LIN-1-2-1-LIN-1-7 THAT FELL OFF THE MASTER SIDE OPEKA-2-LIN-2-1-1-LIN-1-2-1-LIN-3-1 THAT FELL...