  1. Geo Lu

    Circulation pump head calculation in a pressurized closed loop

    Multiple Pumps into a common Header: The most important part in evaluating is to do a dynamic drawing of the process: (i.e.) our situation were 4 pumps into a common header Draw the main header and underneath it draw 4 vertical pipes connecting into the main header. Assign various PSI values...