Hi,
To be more specific: for the same total flow, does the system curve change for 1 or two pumps?
(please check the below data find in https://www.eng-tips.com/viewthread.cfm?qid=458044 )
Many thanks for your help
Q System Curves for 1 Pump System Curves for 2 Pumps
(gpm) Min (ft)Avg...
thread378-458044
I was expecting that system curve did not change in case of multiple pumps. However in thread378-458044, for the same flow, the system curve shows higher head for 2 pumps in comparison to 1 pump.
I should be grateful to get an explanation
Many thanks
I'm trying to generate a system curve (for pump 2) from Epanet following the thread
https://www.eng-tips.com/viewthread.cfm?qid=458044#post
thread378-458044
The problem is that my network is a closed system...and I don't know where to insert the reservoir
at the discharge portion...and how...