Thank you so much , shvet. I will take them into consideration. As l know stagnant flow could also happen in conventional manifold If the test header is not in use for an extended period, the fluid inside can become stagnant.
If you can clarify how that happens in Multi port selector valves!
Thank you so much Littlench. One of the justifications for using is that they are with less cost comparing to conventional manifold as consultant claims, i agree with all what you said. I hope other members involve in this thread to add more information.. some engineers do not recommend them...
Dear engineers,
We are in the FEED stage of designing a facility to produce 50 KBOPD. We have 6 well pads to achieve this production. Each well pad is with an oil gathering manifold. The consultant recommends the manifolds be provided with a multiport selector valves, comprising a housing with...
As mentioned in ASME BPVC 2023 Section XIII 2023 part 9.2.1 blowdown "
(a) Pressure relief valves for compressible fluids having an adjustable blowdown construction shall be adjusted prior to testing so that the blowdown does not exceed 5% of the set pressure or 20 kPa (3 psi), which-ever is...
Hi, dear engineers
We have an oil and gas processing project, we requested the supplier to provide us with two oil trunk lines 16".
their specifications are API 5L PSL2 X52NS SAWL, but the supplier requested changing N condition to Q condition to be able to manufacture them since they can not...