what is the roof construction supported by this truss?
TYPICAL ROOF SHEETING
what are the supporting members at each end?
SUPPORTED BY RC COLUMN
are there ceiling finishes, mechanical and electrical, sports equipment, cranes, etc. Attached to the bottom?
CATWALK ELECTROMECH, ETC
IM THINKING OF...
Yes i do not worry about that. Theres e load combination were dead load is reduced and live load is omitted to reduce the effect of the counterweight
0.9dl + windloas
Thank you for your inputs everyone.
Yes unfortunately the depth is low thats why the governing load combination is 1.2dl+1.6ll
And unfortunately since this is a govermenment project (if you know what I mean), I opt to use the most common steel available which is A36 and getting a large section...
Hi.
I have been designing this 60meter span truss for a multipurpose sports arena.
But using the live load indicated in our local code (PH), it says that the roof live load is 0.6kpa.
With this, 0.6kpa load is not that big if the span and area is small, but using 0.6kpa to a 60m span and 7.5m...