  1. GleeGloomGear

    Seeking Team Support to Overcome Gasket Replacement Challenges in Pipeline Valve Station

    now after loosening the flange between the flange faces is around 16 mm. I only need around 25 mm to remove and install the new gasket. But speaking for cooling what could the possible way to the pipeline, and how we could do that safely with effecting the material structure of carbon steel...
  2. GleeGloomGear

    Seeking Team Support to Overcome Gasket Replacement Challenges in Pipeline Valve Station

    thank you for the support and clarification, the pipe size is 56" thickness is 0.8 inch material: Carbon steel Grade: X70 to clarify these are not elbow bend, but field bend. for the pipe temperature I do not have the exact temperature, but the weather temperature at day is around 45 C and...
  3. GleeGloomGear

    Seeking Team Support to Overcome Gasket Replacement Challenges in Pipeline Valve Station

    I'm currently facing a challenging situation with a new pipeline project involving a valve station where we need to replace a gasket. Despite loosening all flange bolts, we have not been able to achieve the required gap for a proper gasket replacement. Project Overview: The valve station's...