Thanks LittleInch for your time.
The steam temperature is around 400C and pressure around 0.8 to 1 bar. Therefore it is very dry? Can it create that much high condensate.
Contacted the vendor, and got a feedback from their sales team. But it was not convincing.Will try to get their technical...
Sorry LittleInch,
That was a first timer's mistake. Corrected and attached the image of the document.
I used the link in the bottom of the page to upload attachements to Engineering.com
Thanks LittleInch and mk3223 for your time.
The document with all the requested details (such as max Dp is 2 bar, if higher it will lead to condensate backup etc.) is attached for your reference.
Another interesting data is that the capacity of this trap is around 2500kg/hr (very high).
Hope...
Thanks MK3223 for the feedback.
The link is informative.
However it doesnt explain the reason why condensate backup will occur(as mentioned by the vendor) if the DP is more than the designed limit.
My understanding is that the float should rise up regardless of the high DP or high inlet...
Good Day Everyone,
Hope all is well.
We have a free float type steam trap (JH7RH-P) with a maximum differential pressure of 2 bar.
What happense if the differential pressure is more than 2 bar and the trap is full of condensate.?
Trap is mechanically designed for 100 barg.
As per the...