Hello,
A client is requesting for X70 API 5L but the dimensions of the pipe is out of the table 9 " Permissible Specified Outsie Diameter and Specified Wall Thickness".
18" x 92mm . According to table 9 the maximum WT for this OD is 45mm (1.771 inch).