These tests are being requested by the owner - they are not required. The specifications written by the owner reference the ASME B&PVC, not the NBIC. My questions are regarding what the ASME B&PVC says about Pressure Change Tests and Bubble Tests.
Can someone help me with some issues regarding hydrostatic testing of pressure vessels? The pressure vessels are existing equipment that has been in use many years.
"Pressure vessels shall be leak tested using the Pressure Change Test in accordance with ASME Boiler and Pressure Vessel...