Secondary bracing members used in towers and antenna supporting structures allows a resisting force between 1.5% tp 2.5% of the axial design compressive force in the supported member. This is given in Canadian Code S37-01.
Fs(tension/compression) = (0.015+0.008*(L/r-60)) * Cf
Cf = axail design...