Hello,
I changed a year ago from job, now at my new plant we are starting to draw P&ID's (finaly). They have selected the ISO3511 norm als there standaard but I used to work, in my former companies (chemical plants) with the ISA S5.1.
What is the most common used norm in the chemical industry...
Hello
We're struggeling for many months with an isolator problem in the electrolyse plant.
What's the problem:
We've numeros cranes which or working above the elektrolyses celles and they or elektrical separated
from the rest of the building. For this reason we use isolator blocks between the...
Hello,
We've got a small problem at our waterpurification installation. Our wastewater is on the one hand compensated with HCl and on the other hand with Javel(NaOHCl2). We use small water flushpots with our Redox and pH measurement probes. Those water flushpots our connected to our piping with...
Hello,
Connecting a TDC3000 through OPC is very unlikely. I'me not saying it isn't possible, but I would like to see how they going to connect to the APM or HPM cpu's. With our newer system (Experion) everything is possible but with the old TDC it's not economicly interesting.
Now my question...
Hi,
We've have a discussion about a centrifugal pump which is driven by an Frequency converter. I believe that your frequency converter only can use a small part of your pumpcurve. My collegue is saying that you can use the full scale off the pump. In other words you can use from 10 to 60 Hz of...
Hi there,
I've installed recently a cooling compressor and Plc used was an Siemens S7-300. Next month were gonna install a bigger one and again were gooing to use a Siemens PLC but this time a S7-400H.
Other PLC's used or Johnson Control, Steffa, Honeywell, DDC eso.
Rudi
Hello,
Is there somewhere on the web some good information/software for defining/engineering controlvalves for the chemical industrie?
Any help is highly appreciated.
Rudi
Hi,
I'm still missing one WINCC of Siemens. I've worked with WinCC ver 5.2 but ver 6.0 now also uses for scripting VBS they also changed from database Sybase to MSSQLServer.
Also worked with Citect, Genesis, IC2000 and Intouch but not much differnce between those.
Rudi
Hello,
I'm strugling for a few days with a syntax error in some scripting code I wrote for Intouch.
I'm trying to connect to an SQLServer. I can connect and disconnect but when I'm trying the function SQLSelect I always get an faultmessage...
Hello,
I've found the solution, I just reduced the second screen and copied it into the first screen and made it invisible. So now everyting works in the background.
Rudi
Hello,
I'm using WinCC ver 6.0 and i've build several screens. One of those screens has to be active all the time, also when another screen is selected. How can I do this?
Now the screen has to be displayed otherwise it doesn't work.
Rudi
Hello,
Coriolis meters worked for me, We have about 40 installed. We took them in our preventive maintenance program. Every two years we flush and clean them because our product is leaving a small film on the inside of the two tubes of the coriolis. Which have effect on the measurement...
Hello Salma,
I've got one small thing left to ask you if you don't mind?
I'm trying to make a Hardcopy of the screen. I know there is a special function for it but I would like to put it behind a button. I think that's possible but do you know the code in VBS?
Thanks in advance Rudi
Hello everybody,
I'm facing at the moment a small problem with VBS. I'm writing data from WinCC towards a SQL Server, that part works but with retrieving this data I got a problem.
I send a date to a Table in an SQL Server
WinCC (datatype) Tex tag 8 bit character set
SQL (datatype)...